9 Flue terminals Accessories QSG-series Type applicable on article no. price € Heat pump HPX 06 QSG 6+10/20 GHW8000 3675 Heat pump HPX 12 QSG 12+20/30/40 GHW8006 4725 Heat pump HPX 16 QSG 16+x GHW8008 5125 Smart Controller, as standard supplied together with the QSG booster unit all QSG types IW8050 - Power isolation switch for inside and outside 230 V - 400 V, 25 Amp. all QSG types IK5281 78 Roof duct for heat pump ø100mm all QSG types IW8032 125 Suspension brackets S QSG 6+10/20 GA8610 186 Suspension brackets M QSE 12+x and QSE 16+x GA8580 194 DDV 80/125 HR Roofterminal* all QSG types IA8214 167 CT 80/125 HR Wall terminal* all QSG types IA8216 142 x = type booster 20 - 30 - 40 - 50 For flue material see page 18/19 1 2 3 4 ød øD HOH A B E F QSG 80 125 110 1370 575 610 135 Technical data Qwikshift QSG Type Price (incl. Smart Controller) € 7875 8400 9450 9975 11025 10625 11150 12200 13250 Total heating capacity kW 18.0 25.2 31.2 41.0 50.8 34.9 44.7 54.5 64.0 Type corresponding heat pump* HPX 06 HPX 06 HPX 12 HPX 12 HPX 12 HPX 16 HPX 16 HPX 16 HPX 16 Maximum power heat pump** kW 6.0 6.0 12.0 12.0 12.0 16.0 15.7 15.7 15.7 Minimum power heat pump** kW 2.4 2.4 4.8 4.8 4.8 6.3 6.3 6.3 6.3 Maximum power Booster kW 12.0 19.2 19.2 29.0 38.8 19.2 29.0 38.8 48.3 Minimum power Booster kW 4.2 6.4 9.0 9.5 12.8 9.5 9.5 12.8 15.9 Cooling capacity*** kW 6.5 6.5 12 12 12 15.4 15.4 15.4 15.4 Air output max. power (warm) m³/h 1800 1800 4500 4500 4500 6700 6700 6700 6700 Throw horizontal (max.) m 15 15 20 20 20 25 25 25 25 Voltage indoor unit (50hz) V 230V 230V 230V 230V 230V 230V 230V 230V 230V Max. electrical current booster. per phase A 1.5 1.5 1.6 1.6 1.6 3.2 3.2 3.2 3.2 Electrical current outdoor unit (max.) A 11.0 11.0 11.5 11.5 11.5 12.5 12.5 12.5 12.5 Weight kg 57 62 120 120 125 145 145 155 160 Gas consumption G25 m³/h 1.3 2.1 2.1 3.2 4.2 2.1 3.2 4.2 5.3 Gas consumption G20 m³/h 1.5 2.4 2.4 3.6 4.8 2.4 3.6 4.8 6.0 Gas consumption propane G31 kg/h 1.0 1.6 1.6 2.4 3.2 1.6 2.4 3.2 4.0 Water connection G” 3/4 3/4 1 1 1 1 1 1 1 Water volume coil L 2 2 3.9 3.9 3.9 6.6 6.6 6.6 6.6 Sound level dB(A) 35-54 35-54 35-62 35-63 35-63 35-61 35-62 35-62 35-62 Nox-emission (GCV) mg/kWh 30 21 14 33 40 14 33 40 31 Flue terminal length (max.) m 9 9 9 9 9 9 9 9 9 * The QSG booster unit and the heat pump should be ordered separately; the booster unit is supplied with Smart Controller included ** At water temperatures 35°C/30°C and room temperature 20°C, according to EN1397. *** At water temperatures 12°/17°C, room temperature 27°C, 50% RH, according to EN1397. Unit QSG 6+10 QSG 6+20 QSG 12+20 QSG 12+30 QSG 12+40 QSG 16+20 QSG 16+30 QSG 16+40 QSG 16+50
RkJQdWJsaXNoZXIy MTE2OTgy